    ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

    Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
    Description

    Product Description:

    Name:ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

    Type:ORP10

    Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.

    ■ ORP measurement

    ■ Output Interface with RS485, Voltage, Current

    ■ High accuracy with excellent stability

    ■ Reverse power protection and Built-in TVS/ESD protection


    Specifications


    Output Interface

    Analog Voltage 0-2V        

    (Output resistance ~0ohm)

    Analog Current 4-20mA        

    (Load Resistor<500ohm)

    RS485        

    Modbus-RTU

    Power Supply

    3.9-30V/DC

    12-30V/DC

    3.9-30V/DC

    Power Consumption

    10mA@24V DC

    30mA@24V DC        

    (with 20mA output signal)

    10mA@24V DC

    ORP Measurement

    Range:+/-2000mV,Resolution:1mV,Accuracy:±2%

    IP Ratings

    Electrode:IP68        

    Transmitter:IP65

    Operating Temperature

    -40~85℃

    Installation

    Electrode:3/4″NPT screw threads        

    Transmitter:Mounting hole

    Cable Length

    Power and Signal Cable:2 meters or Customize        

    Electrode Cable:5 meters

    Dimension

    Electrode:3/4″NPT screw threads        

    Transmitter:128*70*42mm



    Parameters

    Code

    Comments

    Code 1:        

    Product Series

    ORP10

    ORP10 transmitter

    Code 2:        

    Power Supply

    A        

    B

    3.9-30V DC        

    3.3-16V

    Code 3:        

    ORP Range

    A        

    B

    C

    +/-2000mV        

    +/-1000mV

    Customize

    Code 4:        

    Output Interface

    A        

    B

    C

    D

    E

    F

    G

    Analog Voltage 0-2V        

    Analog Current 4-20mA

    RS485,Modbus-RTU

    RS485,Modbus-RTU & Analog Voltage 0-2V

    RS485,Modbus-RTU & Analog Current 4-20mA

    SDI-12

    Customize

    Code 5:        

    Cable Length

    002        

    XXX

    Electrode Cable:5 meters , Power and Signal Cable:2 meters        

    Electrode Cable:5 meters , Power and Signal Cable:xxx meters

    Ordering Code Example:

    ORP10 transmitter Power Supply 3.9-30V DC, ORP Range +/-2000mV, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ORP10 – A A C 005