    High and low temperature heating chamber BND-HGD1

    Product Description:Name:High and low temperature heating chamberType:BND-HGD1Purpose:It is applicatable for the testing of the indices of spacelight and aviation products,information eletronic instruments and meters,materials,and eletronic and eletrical compenents and parts in high-temperature,low-temperature,humid amd heat environment.
    Description

    Product Description:

    Name:High and low temperature heating chamber

    Type:BND-HGD1


    Purpose:

    It is applicatable for the testing of the indices of spacelight and aviation products,information eletronic instruments and meters,materials,and eletronic and eletrical compenents and parts in high-temperature,low-temperature,humid amd heat environment.


    Product Spec.and Technical parameter table

    model

    HGD1-02K

    HGD1-04K

    HGD1-10K

    HGD1-02K

    HGD1-04K

    HGD1-100K

    HGDL1-02K

    HGDL1-04K

    HGDL1-10K

    volume

    225

    408

    1000

    225

    408

    1000

    225

    408

    1000

    temperature range

    ﹣20~﹢150ºC

    ﹣40~﹢150ºC

    ﹣70~﹢150ºC

    humidity range

    25~98%RH

    temperature fluctuation

    ±0.5ºC(no-load)

    temperature deviation

    ±2.0ºC

    humidity deviation

    ±3.0%RH(>75%RH)±5.0%RH(≤75%RH)

    heating time

    ﹣20~﹢150ºC

    ﹣40~﹢150ºC

    ﹣70~﹢150ºC

    ≤60min

    cooling time

    ﹢20ºC~﹣20ºC

    ﹢20ºC~﹣40ºC

    ﹢20ºC~﹣70ºC

    ≤45min

    ≤60min

    ≤80min

    inside dimension(mm)

    W

    500

    600

    1000

    500

    600

    1000

    500

    600

    1000

    H

    750

    850

    1000

    750

    850

    1000

    750

    850

    1000

    D

    600

    800

    1000

    600

    800

    1000

    600

    800

    1000

    exterior dimension(mm)

    W

    910

    1010

    1410

    910

    1010

    1410

    910

    1010

    1410

    H

    1730

    1830

    1980

    1730

    1830

    1980

    1730

    1830

    1980

    D

    1173

    1373

    1588

    1173

    1373

    1588

    1173

    1373

    1588

    attemperation & humidifying

    Balance Thermal Control (BTC)

    Environment temperature

    +5ºC-+35ºC

    material

    shell

    Double cooling steel plate which sprayed with plastic.

    Inner dimension

    steel plate SUS 304

    insulate

    Rigid Polyurethane Foam + Glass fibre

    Regulating system

    heater

    nickel chromium heater

    humidifier

    stainless steel with heater (heating or humidity in the basin )& boiler

    blower

    centrifugal blower

    refrigeration compressor

    fully enclosed and low noise compressor

    refrigerant

    R404A

    R404A/R23

    cooling mode

    Mechanical compression, one-stage refrigeration refrigeration(air-cooling or water-cooling)

    Mechanical compression of  binary cascade  refrigeration(air-cooling or water-cooling)

    Controller

    monitor

    5.7 Inch color LCD panel

    Mode of operation

    procedure&set

    Method of Setting

    Touch the English or Chinese into the form

    procedure volume

    set the program of 120 groups of different conditions at the same,choose any group or parts to perform cycle work.In each group,1200 different temperature and time can be set at most(eEach section of the maximum is 999h59min).120 groups of procedures can be arbitrary connection,the most cycle can reach 999 times.

    Display resolution

    0.01ºC;0.1min;0.01%RH

    input

    Pt100 RTD

    Communication Interface

    R232 interface

    Method of control

    anti-windup PID

    Water supply

    method

    pumped

    water Tank

    built-in

    Quality of water

    resistance>500Ω

    Power Supply

    AC380(1±10%)V(50±0.5)Hz Three-phase four-wire+protective earth wire

    Maximum current(A)

    14

    14

    24

    14

    14

    25

    21

    21

    38

    installed capacity(KW)

    6

    6

    11

    7

    7

    12

    10

    10

    18

    Weight(KG)

    350

    350

    700

    350

    400

    750

    400

    500

    800

    safety device

    ELCB,Fan overheating protection,Compressor overpressure,overheating,OCP,Phase order protection,overheat, temperature fuse,Dry protector,Water system protection,Water break .