    Photovoltaic Auto safety comprehensive tester

    Product Description:Name:Photovoltaic Auto safety comprehensive testerType:BND-CS9933EG-15Standards: IEC61730; IEC61215; IEC 61646Description of PV safety tester:Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.
    Description

    Product Description:

    Name:Photovoltaic Auto safety comprehensive tester

    Type:BND-CS9933EG-15

    Standards: IEC61730; IEC61215; IEC 61646


    Description of PV safety tester:

    Photovoltaic safety tester is used to test PV module, cable, connector, terminal box, …etc which can deal with high voltage and high sensitivity insulation test. There are two functions that are high voltage test and insulation resistance test in total.

    According to the IEC61730 standard(photovoltaic module safety qualification—part I: Requirements for construction which describes the fundamental construction requirements for photovoltaic modules in order to provide safe electrical and mechanical operation during their expected lifetime), the definition of PV module application is divided into A, B, C.

    The current measuring terminal can choose the grounding mode or the floating mode. Insulation voltage withstand test of photovoltaic module is based on the application of IEC61215/61646 and the maximum voltage of the system.

    Maximum test voltage for the application class A:2000V plus 4 times the maximum system voltage

    For the maximum voltage application category B:1000V system 2 times

    According to the calculation of a maximum voltage of 8000V, CS9923GS, CS9923G is based on this standard production

    According to the calculation of the maximum voltage B 6000V, CS9922G, CS9922GS is based on this standard production


    Performance characteristics:

    ◆With safety anti-electric wall function, it can automatically detect whether the input power is correct

    ◆For photovoltaic system panels, controllers, and battery packs

    ◆After the DC withstand voltage and insulation resistance tests are completed, the tester can quickly discharge within 0.2 seconds to protect the safety of the operator

    ◆With current lower limit alarm function, it can prevent the open circuit of the test line from causing misjudgment of the tested components during the test. The output voltage has voltage upper limit and voltage lower limit alarm functions

    ◆With keyboard lock function to prevent the operator from modifying the test parameters and ensure that the tested object is tested according to the set parameters

    ◆Linear power amplifier drives the output of sinusoidal voltage (current), and the crest factor is within the range of 1.3 to 1.5

    ◆Adopts 240*64 graphic LCD display and humanized interface design

    ◆With Chinese and English display interfaces, it can meet the different needs of different users.

    ◆Test parameters can be saved in advance: 30 files can be set, and each file can have 99 test steps

    ◆Optional RS232, RS485, USB interface, standard PLC interface

    pv-auto-safety-tester (1).jpg


    The Specification of the PV safety test system:

    Model

    BND-CS9933EG-15









    ACW


    The output voltage

    Range

    0.050kV~6.500kV

    Accuracy

    ±(1.5% reading + 5V)

    Resolution

    1V

    Maximum output power

    130VA(6.500kV/20mA)

    Maximum rated current

    20mA

    Lower current range

    0~20mA, 0=no lower limit

    Current range

    200uA, 2mA, 20mA

    Output waveform

    Sine wave

    Output waveform distortion

    ≤2% (no load or pure resistive load)

    Crest factor

    1.3~1.5

    Output signal type

    DDS+ amplifier

    Voltage rise time

    0.3s~999.9s 0=voltage rise time off

    Test time

    0.3s~999.9s 0=continuous test

    Voltage fall time

    0.3s~999.9s 0=voltage fall time off

    Interval time

    0.0s~999.9s 0=interval time off

    Output voltage mode

    N-mode, G-mode







    DCW






    The output voltage

    Range

    0.050kV~6.500kV

    Accuracy

    ±(1.5%Value +5V)

    Resolution

    1V

    Maximum output power

    65W(6.500kV/10mA)

    Maximum rated current

    10mA

    Current range

    2uA、20uA、200uA、2mA、10mA

    Ripple factor

    ≤5%

    Discharge time

    ≤200ms

    Maximum charge current

    10mA

    Voltage rise time

    0.3s~999.9s 0=voltage rise time off

    Test time

    0.3s~999.9s 0=continuous test

    Voltage drop time

    0.3s~999.9s 0=voltage drop time off

    Interval time

    0.0s~999.9s 0=interval time off

    Delay alarm time

    0.3s~999.9s 0=delay alarm time off

    Output voltage mode

    N mode, G mode


    IR



    The output voltage

    Range

    0.050kV~1.500kV

    Accuracy

    ±(1.5% reading +5V)

    Resolution

    1V

    Maximum upper limit setting value

    50.00GΩ




    Maximum and minimum setting values

    50.00GΩ

    Minimum setting values

    1MΩ

    Voltage rise time

    0.3~999.9s 0=voltage rise time off

    Test time

    0.3s~999.9s 0=continuous test

    Interval time

    0.0s~999.9s 0=interval time off

    Automatic gear switching

    Can be set to on or off

    Discharge time

    ≤200ms







    GR


    Output current

    Range

    3.00A~52.00A(DC)

    Accuracy

    ±(1.5% Value +0.2A)

    Resolution

    0.01A

    Maximum output power

    250W(50A/0.10Ω)

    Maximum output current

    50AW

    Resistance upper limit setting value

    40A x150mW

    Set current value

    Output waveform

    Sine wave

    Output waveform distortion

    ≤2% (no load or pure resistive load)

    Crest factor

    1.3~1.5

    Output signal type

    DDS+power amplifier

    Test time

    0.3s~999.9s 0=continuous test

    Interval time

    0.3s~999.9s 0=interval time off

    Voltmeter


    Range

    0.050kV~6.500kV

    0.050kV~6.500kV

    0.050kV~6.500kV

    0.050kV~6.500kV

    Accuracy

    ±(1.5% reading +5V)

    Resolution

    1V

    Display value

    RMS value



    Withstand voltage ammeter

    Measure range

    AC

    0 ~ 20mA

    DC

    0 ~ 10mA


    Resolution

    AC

    200uA: 0.1uA, 2mA: 1uA, 20mA: 10uA

    DC

    2uA: 0.001uA, 20uA: 0.01uA, 200uA: 0.1uA, 2mA: 1uA,

    10mA: 10uA

    Measurement accuracy

    ≥2mA: ±(1.5%+5 digits), <2mA: ±(2%+5 digits)

    Offset function

    The current of the test leads and accessories can be subtracted.

    Test mode

    GND mode: RETURN terminal connected to the chassis

    FLOAT mode: RETURN terminal not connected to the chassis


    Measurement range

    1MΩ~50000MΩ


    Resolution

    1MΩ~9.999MΩ:0.001MΩ,10MΩ~99.99MΩ:0.01MΩ,

    100MΩ~999.9MΩ:0.1MΩ,1000MΩ~9999MΩ:1MΩ

    10GΩ~50GΩ:10MΩ

    Insulation resistance meter



    Accuracy

    0.100kV~0.200kV:1MΩ~999MΩ ±5%,1000MΩ~3000MΩ ±10%

    0.201kV~0.499kV:1MΩ~999MΩ ±5%,1000MΩ~5000MΩ ±10%

    0.500kV~1.000kV:1MΩ~999MΩ ±5%,1000MΩ~9999MΩ ±10%

    10000MΩ~50000MΩ ±15%

    Ground current meter

    Measuring range

    3.00A~52.00A

    Resolution

    0.01A

    Accuracy

    ±(1.5% of reading + 0.2A)

    Display value

    RMS value

    Ground resistance meter

    Range

    0~510mΩ

    Accuracy

    When the current is less than 5.00A, it is ± (3% of reading + 3mΩ) When the current is ≥ 5.00A, it is ± (2% of reading + 2mΩ)

    Resolution

    0.1mΩ

    Measuring method

    Four-terminal method

    Timer

    Range

    0~999.9s

    Resolution

    0.1s

    Accuracy

    ±(0.1%+50ms)