    IEC 60335/IEC 60065 Residual Voltage Tester

    Product Description:Name:IEC 60335/IEC 60065 Residual Voltage TesterType:BND-RVT-3000WResidual Voltage Tester is according to the below standards:IEC 60335-1 Clause 22.5 (GB4706.1 Clause 22.5),IEC 60065 Clause 9.1.6 (GB8898 Clause 9.1.6),
    Description

    Product Description:

    Name:IEC 60335/IEC 60065 Residual Voltage Tester

    Type:BND-RVT-3000W


    Residual Voltage Tester is according to the below standards:

    IEC 60335-1 Clause 22.5 (GB4706.1 Clause 22.5),

    IEC 60065 Clause 9.1.6 (GB8898 Clause 9.1.6),

    IEC 60601-1 (GB9706.1 Clause 15),

    IEC/EN 60598-1 Clause 8.2.7 (GB7000.1 Clause 8.2.7)

    and IEC 60950-1 ( GB4943.1 Clause 2.1.1.7).


    The BND-RVT-3000W Residual Voltage Tester can disconnect the tested equipment from the grid voltage at peak value, and the insulation resistance after the disconnection circuit is sufficiently large to simulate the method of pulling out the plug. It can be used for electrical equipment plug discharge and residual voltage testing of household appliances, audio and video equipment, medical devices, lighting fixtures, information technology equipment, and other electrical devices.

    The instrument has a high enough test impedance using the method of analog unplugging to disconnect the equipment from the power grid voltage at the peak state, which is used for the residual voltage test of medical equipment, household appliances and other electrical equipment.


    Specification:

    output voltage/AC

    0 ~ 245V

    test voltage

    0 ~ 150V

    test time

    1 second

    test impedance

    1000 MΩ

    test alarm range

    60/34V

    test discrimination

    sound and light alarm, while cutting off the voltage

    equipment size

    L 450*W450*H 200mm

    Display model

    touch screen

    Working power supply

    AC220V/50Hz


    Performance characteristics:

    (1) Power off test when the equipment power supply voltage is peak, to ensure the accuracy and consistency of the test data;

    (2) Test impedance ≥1000MΩ, to meet the impedance requirements of L-E electrode and palpable capacitor residual voltage and energy test;

    (3) Multi-form test function. A. Residual voltage between each power supply pin;

    B. The remaining voltage between each power pin and the device housing;

    C. Residual voltage and energy test of accessible capacitors outside the equipment;

    (4) Manual/automatic conversion test. That is, the phase separation test between electrodes can be carried out manually, and the test is 10 times every 2 electrodes. Automatic testing can also be carried out to complete the test of the combination between the three poles, each combination is tested 10 times;

    (5) Automatically maintain the maximum test voltage value, and the test residual voltage exceeds 60/34V.